Solid phase extraction device uses selective adsorption

固相萃取装置和无油真空泵一起使用图片.jpg

Shanghai Xinzhuang Instrument Co., Ltd. LZ brand solid phase extraction device - solid phase extraction principle Solid Phase Extraction (SPE) is a sample pretreatment technology developed from the mid-1980s. It is developed by a combination of liquid-solid extraction and liquid chromatography. Mainly used for sample separation, purification and enrichment. The main purpose is to reduce sample matrix interference and improve detection sensitivity.

The SPE technology of solid phase extraction device is based on the theory of liquid-solid phase chromatography. The method of selective adsorption and selective elution is used to enrich, separate and purify the sample. It is a physical extraction process including liquid phase and solid phase. It can be approximated as a simple chromatographic process.

The solid phase extraction device SPE is a liquid chromatography separation principle using selective adsorption and selective elution. The more common method is to pass the liquid sample solution through the adsorbent, retain the substance to be tested, and then use the appropriate strength solvent to wash away the impurities, and then quickly elute the test substance with a small amount of solvent, thereby achieving the purpose of rapid separation, purification and concentration. It is also possible to selectively adsorb the interfering impurities and let the measured substance flow out; or simultaneously adsorb the impurities and the tested substance, and then selectively elute the test substance with a suitable solvent.

Solid phase extraction device solid phase extraction operation steps:

The operation is slightly different for the difference in the retention mechanism of the filler (the filler retains the target compound or retains impurities).

Solid phase extraction operations generally have four steps

First, the filler retains the target compound

1. Activation----Remove impurities in the small column and create a certain solvent environment.

2. Load----Dissolve the sample with a certain solvent, transfer it to the column and keep the components on the column.

3, rinse----Maximize the removal of interference.

4. Elution----The substance to be tested is eluted and collected with a small volume of solvent.

Second, the filler retains impurities

Solid phase extraction operations generally have three steps

1. Activation - removes impurities from the column and creates a solvent environment.

2, loading - transfer the sample into the column, at this time most of the target compound will flow out with the sample base, impurities are retained on the column,

So this step is going to start collecting

3. Elution - The components are rinsed down with a small volume of solvent and collected, and the pool is combined.

This is often used to remove pigments in food or pesticide analysis.

For more information about solid phase extraction equipment, please contact Shanghai Xinzhuang Instrument Co., Ltd., Shanghai Xinzhuang Instrument Production and Development of solid phase extraction device 12 holes, 24 holes, unified control, independent control, welcome to inquire!

Http://

KDLED700+500 (3)

LED-Q5

Germany imported beads

Imported French lens

mould Die-casting  Eight edge type Revolving arm

Optional emergency power supply≥3 hours


led (1)

Led operating light

1)Ideal cold light effects

Using the new LED cold light source, ensure energy saving and environmental protection and long service life up to 80,000hours and more.

The temperature increase of surgeon`s head below 1℃. LED do not engender infrared ray and ultraviolet radiation, without the temperature

rise and tissue damage caused by halogen shadowless light, also it can accelerate the wound healing after surgery, and without Radiation pollution.

With color temperature constant and soft, LED is very close to the sunshine.

1) Excellent shadowless effect

Lamp with the most scientific radian and Multi point light source design, ensure better uniform illuminance. When the lamps are partially occluded,

also can achieve perfect shadowless effect.Lamp panel radius of gyration ≥182cm, the lamp can be pulled to vertical floor, convenient to any angle illumination.

2) Excellent deep lighting

It is based on modularize method by Computer Aided Design, focused to irradiating with more beams of LED. It produces the deep lighting which beams

more than 1200cm,the illumination of center up to 180,000Lux or more, and offer the color temperature that can be adjusted from 3700K to 5000K which

is close to sunshine. Absolutely, it really reflects the color of human tissue and satisfied by all kinds of operating light needs.

3) Advanced control system

The use of liquid crystal display button control, to meet the needs of the medical staff of different patients with the brightness of the operation.

It offers illuminance memory function.

It does not effect using when a single circuit or one bulb is broken.

4) Universal suspension system

Rotating arm, a new type of alloy material is made of eight edge type.

Balanced system using imported arm module, more than 5 group universal joints, every cantilever must has more than 3 joints which can be rotated in 360°,

The structure is light, easy to manipulate, accurate positioning, can provide the maximum range of regulation.The equipped with fatigue correcting unit and

fix position hand handle device, easy to fix position after long time use.

5) Modern laminar lamp

The thickest part of lamp-chimney is not more than 10cm.

The lamp-chimney is made of ABS, The handle on the central of lamp can be detachable, can take high temperature (≤ 134°C) sterilization treatment,

easily adjust, flexible fixed.

Double Dome Operating Light

Double Dome LED Operating Light,Double Dome Surgery Operating Lights,Operation Theatre Lights,Surgical Examination Light

Shandong qufu healthyou Medical Technology co.,Ltd , https://www.kangerjian-medical.com

Posted on