Specific steps to calibrate the oscilloscope

(a) Plug in the power cord of the oscilloscope, turn on the power switch, and the power indicator light is on. After the scan line appears, adjust the brightness to the appropriate position, adjust the focus control, and make the scan line the finest. (b) Adjust the baseline knob so that the scan line is parallel to the horizontal scale line.

Oscilloscope use

1) Test steps

(a) Plug in the power cord of the oscilloscope, turn on the power switch, and the power indicator light is on. After the scan line appears, adjust the brightness to the appropriate position, adjust the focus control, and make the scan line the finest.

(b) Adjust the baseline knob so that the scan line is parallel to the horizontal scale line.

(c) Turn the fine adjustment/expansion control switch knob clockwise to the calibration position. To avoid measurement errors, the probe should be inspected and corrected before measurement. The calibration method is: connect the probe to the corrected square wave output of the oscilloscope, and adjust the compensation capacitor of the correction hole on the probe level until the square wave displayed on the screen is a flat top.

(d) The volt/degree selection switch, the working mode switch, and the scan time selection switch are placed in appropriate positions according to the size of the signal to be measured and the frequency.

(e) Place the input coupling switch in the "GND" position to determine the position of the zero level. Then put it in the "AC" position, input the measured signal from the probe, adjust the synchronous switch knob to make the waveform stable, observe the amplitude of the signal waveform displayed on the screen in the vertical direction, and the product of the measured signal voltage V/DIV and the display degree. When using a 10:1 input probe, the screen should display the amplitude value × 10.

2) Things to be aware of during measurement

(a) When measuring, do not place the meter in a place with a strong magnetic field nearby.

(b) The amplitude of the signal under test cannot exceed the specified withstand voltage at each input of the oscilloscope to prevent the oscilloscope's amplifier from being burned out.

(c) When testing, the oscilloscope's case should be suspended to avoid short circuits.

(d) The AC voltage measured by the oscilloscope is the peak-to-peak value.

(e) The test line should be as short as possible, and the probe should be close to the measured point, otherwise it may cause waveform distortion.

We specialize in manufacturing Microscope prepared slides, medical models, rock specimens, microtome, heating mantles, and lab instruments and consumable materials. New technology update. customization is more diversified. More accurate and longer service life. New changes can better meet the requirements of customer orders. Vic employees consider our company a sign of victory and success. We consider every customer of utmost importance. We consider that we have excellent quality products and service. As a young and enthusiastic team, we will work hard to achieve your needs and requirements.With large stock in our factory, we can cope with large and urgent orders promptly at competitive prices. We make all our efforts to meet your needs with our strong advanges.