Enzyme-linked immunoassay of human insulin-like growth factor-â…  (IGF-â… )

Human insulin-like growth factor-â…  (IGF-â… ) ELISA kit instructions for use This kit is for research use only.
Drug Name:
Generic name: Human Insulin-Like Growth Factor-â…  (IGF-â… ) ELISA Kit Purpose of Use:
This kit is used for the determination of insulin-like growth factor-â…  (IGF- in human serum, plasma, tissue or other related tissue fluids
â… ) Content.
Experimental principle This kit uses the sandwich method to determine the level of insulin-like growth factor-â…  (IGF-â… ) in specimens. Coat the microwell plate with purified human insulin-like growth factor-â…  (IGF-â… ) receptor, and add insulin-like growth factor-â…  (IGF-â… ) to the microwells in turn,
It is then combined with HRP-labeled goat anti-human receptor to form an immune complex. After thorough washing, the substrate TMB is added for color development.
TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the insulin-like growth factor-I (IGF-I) in the sample. Measure the absorbance (OD) at 450nm with a microplate reader
Value), calculate the insulin-like growth factor-I (IGF-I) antigen concentration in the sample by the standard curve.
Kit composition
1 20 times concentrated washing solution 30ml × 1 bottle 7 stop solution 6ml × 1 bottle
2 Enzyme label reagent 6ml × 1 bottle 8 standard (240μg / L) 0.5ml × 1 bottle
3 Enzyme label coated plate 12 wells × 8 strips 9 standard dilutions 1.5ml × 1 bottle
4 Sample diluent 6ml × 1 bottle 10 instructions 1 copy
5 Developer A solution 6ml × 1 bottle 11 2 sealing film
6 Developer B solution 6ml × 1 / bottle 12 sealed bag 1 specimen requirement
1. Experiment as soon as possible after specimen collection.
2. Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.
3. The specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.
Steps
1. Dilution and loading of standard products: set 10 standard wells on the enzyme-coated plate, add 100 μl of the standard products in the first and second wells, and then add the standard products in the first and second wells. 50μl of diluent, mix well; then take 100μl from the first well and the second well and add them to the third and fourth wells respectively, then add 50μl of the standard diluent to the third and fourth wells,
Mix well; then take 50μl each in the third and fourth wells and discard them, then add 50μl each to the fifth and sixth wells, and then add 50ul of standard dilution solution to the fifth and sixth wells, Mix; after mixing, take 50μl from the fifth and sixth wells and add them to the seventh and eighth wells respectively. Then add 50μl of the standard dilution solution to the seventh and eighth wells respectively. 7. Take 50μl from the eighth and eighth wells respectively and add it to the ninth and tenth wells. Then add 50μl of the standard dilution solution to the ninth and tenth wells respectively. After mixing, take 50μl from the ninth and tenth wells and discard. (After dilution, the volume of each well is 50μl,
The concentrations are 180μg / L, 120μg / L, 60μg / L, 30μg / L, 15μg / L).
2. Add samples: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the steps are the same) and the sample wells to be tested. Add 40μl of sample diluent to the test sample well of the enzyme-coated plate, and then add 10μl of the test sample (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.
3. Incubation: seal the plate with the sealing film and incubate at 37 ° C for 30 minutes.
4. Mixing solution: dilute 20 times concentrated washing solution with distilled water 20 times and reserve
5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds, then discard, repeat 5 times and pat dry.
6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.
7. Incubation: The operation is the same as 3.
8. Washing: The operation is the same as 5.
9. Color development: add 50μl of developer A to each well, and then add 50μl of developer B, mix gently, and develop color at 37 ℃ in the dark
15 minutes.
10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.
The calculation takes the concentration of the standard as the abscissa and the OD value as the ordinate, and draws a standard curve on the coordinate paper.
The corresponding concentration of OD value is found from the standard curve; then multiplied by the dilution factor; or the linear regression equation of the standard curve is calculated from the concentration of the standard and the OD value, and the OD value of the sample is substituted into the equation to calculate the sample concentration, and then multiplied With a dilution factor,
This is the actual concentration of the sample.
Precautions
1. The kit should be taken out of the refrigerated environment and equilibrated at room temperature for 15-30 minutes before use. If the enzyme-coated plate is unsealed after opening, the strip should be stored in a sealed bag.
2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute it with a certain multiple (n times) of the sample diluent and then determine it. Please multiply the total dilution for the calculation Multiple (× n × 5).
5. The sealing film is limited to one-time use to avoid cross-contamination.
6. Strictly follow the instructions, and the test results must be determined by the microplate reader.
7. The components of different batches of this reagent shall not be mixed. Please keep the substrate away from light.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. If it is different from the English manual, the English manual shall prevail.
10μg / L -200μg / L
specification:
96 servings / box storage conditions and expiration date
1. Kit storage :; 2-8 ℃.
2. Validity: 6 months

JM5 Mid Edge Basin

Mid Edge Basin,Solid Surface Basin,Hand Wash Basin,Bathroom Wash Basin

GUANGDONG ZHIJIE SANITARY WARE CO., LTD. , https://www.zhijiesanitary.com

Posted on